kowledge base banner

How to Validate Tension Load Cell Calibration on Winders

by Bassam Dib, B.ing, Senior Analyst

Load cell calibration can be validated using electrical measurements available from most drive systems. In particular, tension calculated from unwind motor measurements closely matches the effective tension. A 10% factor is used to account for motor efficiency, windage and friction losses in the winder.